Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/28952
Title: Wearable Finger Pulse Oximetry for Continuous Oxygen Saturation Measurements During Daily Home Routines of Patients With Chronic Obstructive Pulmonary Disease (COPD) Over One Week: Observational Study
Authors: Buekers, Joren
THEUNIS, Jan 
DE BOEVER, Patrick 
Vaes, Anouk W.
Koopman, Maud
Janssen, Eefje V. M.
Wouters, Ernie F. M.
SPRUIT, Martijn A. 
Aerts, Jean-Marie
Issue Date: 2019
Publisher: JMIR PUBLICATIONS, INC
Source: JMIR MHEALTH AND UHEALTH, 7(6) (Art N° e12866)
Abstract: Background: Chronic obstructive pulmonary disease (COPD) patients can suffer from low blood oxygen concentrations. Peripheral blood oxygen saturation (SpO(2)), as assessed by pulse oximetry, is commonly measured during the day using a spot check, or continuously during one or two nights to estimate nocturnal desaturation. Sampling at this frequency may overlook natural fluctuations in SpO(2). Objective: This study used wearable finger pulse oximeters to continuously measure SpO(2) during daily home routines of COPD patients and assess natural SpO(2) fluctuations. Methods: A total of 20 COPD patients wore a WristOx(2) pulse oximeter for 1 week to collect continuous SpO(2) measurements. A SenseWear Armband simultaneously collected actigraphy measurements to provide contextual information. SpO(2) time series were preprocessed and data quality was assessed afterward. Mean SpO(2) , SpO(2) SD, and cumulative time spent with SpO(2) below 90% (CT90) were calculated for every (1) day, (2) day in rest, and (3) night to assess SpO(2) fluctuations. Results: A high percentage of valid SpO(2) data (daytime: 93.27%; nocturnal: 99.31%) could be obtained during a 7-day monitoring period, except during moderate-to-vigorous physical activity (MVPA) (67.86%). Mean nocturnal SpO(2) (89.9%, SD 3.4) was lower than mean daytime SpO(2 )in rest (92.1%, SD 2.9; P<.001). On average, SpO(2) in rest ranged over 10.8% (SD 4.4) within one day. Highly varying CT90 values between different nights led to 50% (10/20) of the included patients changing categories between desaturator and nondesaturator over the course of 1 week. Conclusions: Continuous SpO(2) measurements with wearable finger pulse oximeters identified significant SpO(2 )fluctuations between and within multiple days and nights of patients with COPD. Continuous SpO(2 ) measurements during daily home routines of patients with COPD generally had high amounts of valid data, except for motion artifacts during MVPA. The identified fluctuations can have implications for telemonitoring applications that are based on daily SpO(2) spot checks. CT90 values can vary greatly from night to night in patients with a nocturnal mean SpO(2) around 90%, indicating that these patients cannot be consistently categorized as desaturators or nondesaturators. We recommend using wearable sensors for continuous SpO(2 )measurements over longer time periods to determine the clinical relevance of the identified SpO(2 )fluctuations.
Notes: [Buekers, Joren; Theunis, Jan; De Boever, Patrick] Flemish Inst Technol Res VITO Mol, Hlth Unit, Mol, Belgium. [Buekers, Joren; Aerts, Jean-Marie] Katholieke Univ Leuven, Dept Biosyst, Measure Model & Manage Bioresponses, Kasteelpk Arenberg 30, B-3000 Leuven, Belgium. [De Boever, Patrick] Hasselt Univ, Ctr Environm Sci, Diepenbeek, Belgium. [Vaes, Anouk W.; Koopman, Maud; Janssen, Eefje V. M.; Wouters, Ernie F. M.; Spruit, Martijn A.] Ctr Expertise Chron Organ Failure CIRO, Dept Res & Educ, Horn, Netherlands. [Wouters, Ernie F. M.; Spruit, Martijn A.] Maastricht Univ, Dept Resp Med, Med Ctr, Maastricht, Netherlands. [Spruit, Martijn A.] Hasselt Univ, Fac Rehabil Sci, Rehabil Res Ctr REVAL, Biomed Res Inst BIOMED, Diepenbeek, Belgium. [Spruit, Martijn A.] Maastricht Univ, Sch Nutr & Translat Res Metab NUTRIM, Med Ctr, Maastricht, Netherlands.
Keywords: COPD; oxygen saturation; finger pulse oximeter; wearable sensor; nocturnal desaturation; telemonitoring;COPD; oxygen saturation; finger pulse oximeter; wearable sensor; nocturnal desaturation; telemonitoring
Document URI: http://hdl.handle.net/1942/28952
ISSN: 2291-5222
e-ISSN: 2291-5222
DOI: 10.2196/12866
ISI #: 000471677900001
Rights: This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR mhealth and uhealth, is properly cited. The complete bibliographic information, a link to the original publication on http://mhealth.jmir.org/, as well as this copyright and license information must be included.
Category: A1
Type: Journal Contribution
Validations: ecoom 2020
Appears in Collections:Research publications

Files in This Item:
File Description SizeFormat 
36eb26e7-0d01-4325-8165-d9e4d409fce8.pdfPublished version1.08 MBAdobe PDFView/Open
Show full item record

WEB OF SCIENCETM
Citations

53
checked on Apr 23, 2024

Page view(s)

134
checked on Aug 30, 2022

Download(s)

106
checked on Aug 30, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.