dc.description.abstractThis paper discusses and quantifies the minimum requirements of walls and tie-columns in confined masonry (CM) buildings located in earthquake-prone regions. A research database including 238 damaged CM buildings obtained from the 2008 Wenchuan earthquake survey is established and comprehensively examined. The requirements of masonry walls in CM buildings are discussed, and a simplified tie-column density index is proposed for evaluating the potential damage of the structures. Besides, the minimum requirements of reinforced concrete tie-columns and their maximum allowable spacing in CM buildings at different seismic intensity zones are discussed.-
dc.description.sponsorshipThis work was supported by the National Natural Science Foundation of China [51308473]; Department of Housing & Urban-Rural Development of Sichuan province (China) [2014S001];-
dc.language.isoen-
dc.publisherTAYLOR & FRANCIS LTD-
dc.rights2018 Taylor & Francis Group, LLC. This is an author produced version of a paper published in Journal of Earthquake Engineering. Uploaded in accordance with the publisher's self-archiving policy.-
dc.subject.otherConfined Masonry-
dc.subject.otherSeismic Assessment-
dc.subject.otherDesign Requirements-
dc.subject.otherWall Density-
dc.subject.otherTie-Column Density Spacing of Tie-Columns-
dc.subject.otherDatabase of Damaged Buildings-
dc.titleSimplified Density Indexes of Walls and Tie-Columns for Confined Masonry Buildings in Seismic Zones-
dc.typeJournal Contribution-
dc.identifier.epage469-
dc.identifier.issue3-
dc.identifier.spage447-
dc.identifier.volume24-
local.format.pages23-
local.bibliographicCitation.jcatA1-
dc.description.notesSu, QW (reprint author), Southwest Jiaotong Univ, Sch Civil Engn, 111,1st North Sect,2nd Ring Rd, Chengdu 610031, Sichuan, Peoples R China.-
dc.description.notessucai_2016@126.com-
dc.description.otherSu, QW (reprint author), Southwest Jiaotong Univ, Sch Civil Engn, 111,1st North Sect,2nd Ring Rd, Chengdu 610031, Sichuan, Peoples R China. sucai_2016@126.com-
local.publisher.place2-4 PARK SQUARE, MILTON PARK, ABINGDON OR14 4RN, OXON, ENGLAND-
local.type.refereedRefereed-
local.type.specifiedArticle-
dc.identifier.doi10.1080/13632469.2018.1453396-
dc.identifier.isiWOS:000511240200005-
dc.contributor.orcidTsavdaridis, Konstantinos Daniel/0000-0001-8349-3979-
dc.identifier.eissn-
dc.identifier.eissn1559-808X-
local.provider.typewosris-
local.uhasselt.uhpubyes-
item.fulltextWith Fulltext-
item.accessRightsOpen Access-
item.validationecoom 2021-
item.contributorCAI, Gaochuang-
item.contributorSu, Qiwang-
item.contributorTsavdaridis, Konstantinos Daniel-
item.contributorDEGEE, Herve-
item.fullcitationCAI, Gaochuang; Su, Qiwang; Tsavdaridis, Konstantinos Daniel & DEGEE, Herve (2020) Simplified Density Indexes of Walls and Tie-Columns for Confined Masonry Buildings in Seismic Zones. In: JOURNAL OF EARTHQUAKE ENGINEERING, 24 (3) , p. 447 -469.-
crisitem.journal.issn1363-2469-
crisitem.journal.eissn1559-808X-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
Accepted Version.pdfPeer-reviewed author version863.28 kBAdobe PDFView/Open
Show simple item record

WEB OF SCIENCETM
Citations

8
checked on Sep 20, 2024

Page view(s)

32
checked on Sep 7, 2022

Download(s)

28
checked on Sep 7, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.