Please use this identifier to cite or link to this item:
http://hdl.handle.net/1942/31905
Title: | Ductility requirements for the design of bolted lap shear connections in bearing | Authors: | GOUVEIA HENRIQUES, Jose Jaspart, J-P. Silva, L. Simões da |
Issue Date: | 2014 | Publisher: | Source: | Advanced Steel Construction, 10 (1) , p. 33 -52 | Abstract: | The resistance of bolted lap shear connections in bearing is traditionally evaluated by considering an equal distribution of internal forces amongst the bolts. In fact, such an assumption may only be seen as the result of a plastic redistribution of the internal forces, what requires shear ductility in the vicinity of the bolts. In the present paper, ductility requirements are proposed that ensure that, in the presence of real geometric imperfections, plastic resistance can be attained. | Keywords: | Shear bolted connections;equivalent bolt zone component;available deformation capacity;required deformation capacity;ductility criteria | Document URI: | http://hdl.handle.net/1942/31905 | ISSN: | 1816-112X | DOI: | 10.18057/IJASC.2014.10.1.3 | Category: | A1 | Type: | Journal Contribution |
Appears in Collections: | Research publications |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Microsoft Word - 3-12-177-pp33-52_JoseHenriques-Revision.doc.pdf Restricted Access | Published version | 633.36 kB | Adobe PDF | View/Open Request a copy |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.