Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/33051
Title: Test–Retest Reliability of Handgrip Strength Measurement in Children and Preadolescents
Authors: Gasior, Jakub S.
Pawlowski, Mariusz
Jelen, Piotr J.
RAMECKERS, Eugene 
Williams, Craig A.
Makuch, Robert
Werner, Bozena
Issue Date: 2020
Publisher: MDPI
Source: INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 17 (21) (Art N° 8026)
Abstract: The reliability of handgrip strength (HGS) measurement has been confirmed in adults but has been sparsely addressed in pediatric populations. The aims of this study are twofold: to determine whether sex, age and/or hand-dominance influence the test-retest differences and to establish the reliability level of the HGS measurement in typical developing pediatric participants. A total of 338 participants aged 7-13 years were tested using a digital handgrip strength (HGS) dynamometer (Jamar Plus+ Dynamometer) by the same rater on two testing trials separated by a one-day interval between sessions. The HGS testing was conducted according to the American Society of Hand Therapists recommendations. Relative and absolute reliability statistics were calculated. Age influenced the test-retest difference of the HGS measurement as children compared to preadolescents had lower intraclass correlation coefficients (0.95 vs. 0.98), standard error of measurement (SEM) (0.74 vs. 0.78 kg), smallest detectable difference (SDD) (2.05 vs. 2.16 kg) and higher values of the percentage value of SEM (5.48 vs. 3.44%), normalized SDD (15.52 vs. 9.61%) and a mean difference between the test and retest values (0.50 vs. 0.02 kg) for the dominant hand. The results indicate that the protocol using the Jamar digital handgrip dynamometer is a reliable instrument to measure HGS in participants aged 7-13 years with typical development. Clinicians and researchers therefore can have confidence in determining the minimally clinical effect for HGS.
Notes: Gasior, JS (corresponding author), Med Univ Warsaw, Dept Pediat Cardiol & Gen Pediat, PL-02091 Warsaw, Poland.
jgasior@wum.edu.pl; pawlowskimariusz@o2.pl; piotr.jelen@wum.edu.pl;
eaa.rameckers@hetnet.nl; c.a.williams@exeter.ac.uk; r.makuch@uthrad.pl;
bozena.werner@wum.edu.pl
Other: Gasior, JS (corresponding author), Med Univ Warsaw, Dept Pediat Cardiol & Gen Pediat, PL-02091 Warsaw, Poland. jgasior@wum.edu.pl; pawlowskimariusz@o2.pl; piotr.jelen@wum.edu.pl; eaa.rameckers@hetnet.nl; c.a.williams@exeter.ac.uk; r.makuch@uthrad.pl; bozena.werner@wum.edu.pl
Keywords: children;adolescents;muscle strength;grip strength;dynamometer;reliability
Document URI: http://hdl.handle.net/1942/33051
ISSN: 1661-7827
e-ISSN: 1660-4601
DOI: 10.3390/ijerph17218026
ISI #: WOS:000589164100001
Rights: 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Category: A1
Type: Journal Contribution
Validations: ecoom 2021
Appears in Collections:Research publications

Files in This Item:
File Description SizeFormat 
ijerph-17-08026.pdfPublished version937.76 kBAdobe PDFView/Open
Show full item record

WEB OF SCIENCETM
Citations

19
checked on Apr 22, 2024

Page view(s)

26
checked on May 30, 2022

Download(s)

8
checked on May 30, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.