Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/34506
Title: The effect of different lower detection thresholds in microdosimetric spectra and their mean values
Authors: BIANCHI, Anna 
Selva, Anna
Colautti, Paolo
Parisi, Alessio
Vanhavere, Filip
RENIERS, Brigitte 
Conte, Valeria
Issue Date: 2021
Publisher: 
Source: Radiation measurements, 146 (Art N° 106626)
Abstract: Research on the applications of microdosimetry to particle therapy is spreading worldwide with a rapid increase of publications in the last years. In order to be able to perform an intercomparison of data acquired with different detectors in different clinical centres it is important to analyse data with a standard procedure. Often microdosimetric spectra are presented with different lower detection thresholds, in relation with different detection sensitivity and noise levels. The purpose of this paper is to analyse the influence of the lower detection threshold on the dose-mean lineal energy values, which are used as an assessment of the average LET of the radiation field. Furthermore, the dose distribution of the lineal energy can be used in combination with biological weighting functions to estimate the biological RBE at different positions along the penetration depths of therapeutic proton or carbon ion beams. Microdosimetric spectra cut at different lower thresholds lead in principle to different RBE values. It was an additional purpose of this work to analyse and discuss this effect both for proton and carbon ion irradiations. Spectra in proton and carbon ion beams gathered with a miniaturized TEPC developed at the Legnaro National Laboratories of the Italian Institute for Nuclear Physics (LNL-INFN) have been used to perform this study. Linear extrapolation of the microdosimetric spectra to a common value of 0.01 keV/um significantly reduces the deviations in the mean values due to different lower thresholds. It is advisable to perform this procedure to uniform the data analysis and facilitate the intercomparison of data.
Keywords: Microdosimetry;mini-TEPC;Particle Therapy;Linear extrapolation
Document URI: http://hdl.handle.net/1942/34506
ISSN: 1350-4487
e-ISSN: 1879-0925
DOI: 10.1016/j.radmeas.2021.106626
ISI #: 000678534900001
Category: A1
Type: Journal Contribution
Validations: ecoom 2022
Appears in Collections:Research publications

Files in This Item:
File Description SizeFormat 
Author version.pdfPeer-reviewed author version737.15 kBAdobe PDFView/Open
1-s2.0-S1350448721001384-main.pdf
  Restricted Access
Published version2.6 MBAdobe PDFView/Open    Request a copy
Show full item record

WEB OF SCIENCETM
Citations

8
checked on Apr 24, 2024

Page view(s)

38
checked on Sep 7, 2022

Download(s)

6
checked on Sep 7, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.