Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/42431
Full metadata record
DC FieldValueLanguage
dc.contributor.authorLebleu, Julien-
dc.contributor.authorDANIELS, Kim-
dc.contributor.authorPauwels, Andries-
dc.contributor.authorDekimpe, Lucie-
dc.contributor.authorMAPINDUZI, Jean-
dc.contributor.authorPoilvache, Hervé-
dc.contributor.authorBONNECHERE, Bruno-
dc.date.accessioned2024-02-15T14:15:26Z-
dc.date.available2024-02-15T14:15:26Z-
dc.date.issued2024-
dc.date.submitted2024-02-15T08:07:10Z-
dc.identifier.citationSENSORS, 24 (4) (Art N° 1163)-
dc.identifier.urihttp://hdl.handle.net/1942/42431-
dc.description.abstractOsteoarthritis (OA) poses a growing challenge for the aging population, especially in the hip and knee joints, contributing significantly to disability and societal costs. Exploring the integration of wearable technology, this study addresses the limitations of traditional rehabilitation assessments in capturing real-world experiences and dynamic variations. Specifically, it focuses on continuously monitoring physical activity in hip and knee OA patients using automated unsupervised evaluations within the rehabilitation process. We analyzed data from 1144 patients who used a mobile health application after surgery; the activity data were collected using the Garmin Vivofit 4. Several parameters, such as the total number of steps per day, the peak 6-minute consecutive cadence (P6MC) and peak 1-minute cadence (P1M), were computed and analyzed on a daily basis. The results indicated that cadence-based measurements can effectively, and earlier, differ among patients with hip and knee conditions, as well as in the recovery process. Comparisons based on recovery status and type of surgery reveal distinctive trajectories, emphasizing the effectiveness of P6MC and P1M in detecting variations earlier than total steps per day. Furthermore, cadence-based measurements showed a lower inter-day variability (40%) compared to the total number of steps per day (80%). Automated assessments, including P1M and P6MC, offer nuanced insights into the patients’ dynamic activity profiles.-
dc.description.sponsorshipFunding: This research received no external funding.-
dc.language.isoen-
dc.publisherMDPI-
dc.rights2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https:// creativecommons.org/licenses/by/ 4.0/).-
dc.subject.othermHealth-
dc.subject.otherosteoarthritis-
dc.subject.otherpersonalized care-
dc.subject.otherrehabilitation-
dc.subject.otherrehabilomics-
dc.subject.otherwearable sensors-
dc.subject.otheractivity tracker-
dc.titleIncorporating Wearable Technology for Enhanced Rehabilitation Monitoring after Hip and Knee Replacement-
dc.typeJournal Contribution-
dc.identifier.issue4-
dc.identifier.volume24-
local.bibliographicCitation.jcatA1-
dc.description.notesBonnechère, B (corresponding author), PXL Univ Appl Sci & Arts, Dept PXL Healthcare, B-3500 Hasselt, Belgium.; Bonnechère, B (corresponding author), Hasselt Univ, Fac Rehabil Sci, REVAL Rehabil Res Ctr, B-3590 Diepenbeek, Belgium.; Bonnechère, B (corresponding author), Hasselt Univ, Data Sci Inst, Technol Supported & Data Driven Rehabil, B-3590 Diepenbeek, Belgium.-
dc.description.notesjulien@moveup.care; kim.daniels@pxl.be; andries@moveup.care;-
dc.description.noteslucie@moveup.care; mapinduzi.jean@yahoo.fr-
local.publisher.placeST ALBAN-ANLAGE 66, CH-4052 BASEL, SWITZERLAND-
local.type.refereedRefereed-
local.type.specifiedArticle-
local.bibliographicCitation.artnr1163-
dc.identifier.doi10.3390/s24041163-
dc.identifier.pmid38400321-
dc.identifier.isi001172333300001-
dc.identifier.eissn1424-8220-
local.provider.typeCrossRef-
local.description.affiliation[Lebleu, Julien; Pauwels, Andries; Dekimpe, Lucie] MoveUp, B-1000 Brussels, Belgium.-
local.description.affiliation[Daniels, Kim; Bonnechere, Bruno] PXL Univ Appl Sci & Arts, Dept PXL Healthcare, B-3500 Hasselt, Belgium.-
local.description.affiliation[Daniels, Kim; Mapinduzi, Jean; Bonnechere, Bruno] Hasselt Univ, Fac Rehabil Sci, REVAL Rehabil Res Ctr, B-3590 Diepenbeek, Belgium.-
local.description.affiliation[Mapinduzi, Jean] Inst Natl St Publ, Dept Sci Clin, Filiere Kinesitherapie & Readaptat, Bujumbura 6807, Burundi.-
local.description.affiliation[Poilvache, Herve] CHIREC, Orthoped Surg Dept, B-1420 Braine Lalleud, Belgium.-
local.description.affiliation[Bonnechere, Bruno] Hasselt Univ, Data Sci Inst, Technol Supported & Data Driven Rehabil, B-3590 Diepenbeek, Belgium.-
local.uhasselt.internationalyes-
item.fulltextWith Fulltext-
item.fullcitationLebleu, Julien; DANIELS, Kim; Pauwels, Andries; Dekimpe, Lucie; MAPINDUZI, Jean; Poilvache, Hervé & BONNECHERE, Bruno (2024) Incorporating Wearable Technology for Enhanced Rehabilitation Monitoring after Hip and Knee Replacement. In: SENSORS, 24 (4) (Art N° 1163).-
item.contributorLebleu, Julien-
item.contributorDANIELS, Kim-
item.contributorPauwels, Andries-
item.contributorDekimpe, Lucie-
item.contributorMAPINDUZI, Jean-
item.contributorPoilvache, Hervé-
item.contributorBONNECHERE, Bruno-
item.accessRightsOpen Access-
crisitem.journal.eissn1424-8220-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
sensors-24-01163.pdfPublished version971.01 kBAdobe PDFView/Open
Show simple item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.