Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/42741
Title: Early results of a remote dosimetry audit program for lung stereotactic body radiation therapy
Authors: YALVAC, Burak 
REULENS, Nathalie 
RENIERS, Brigitte 
Issue Date: 2024
Publisher: ELSEVIER
Source: Physics & Imaging in Radiation Oncology, 29 (Art N° 100544)
Abstract: Background and purpose: A dosimetry audit program based on alanine electron paramagnetic resonance (EPR) and radiochromic film dosimetry, may be a valuable tool for monitoring and improving the quality of lung stereotactic body radiotherapy (SBRT). The aim of this study was to report the initial, independent assessment of the dosimetric accuracy for lung SBRT practice using these dosimeters in combination with a novel phantom design. Materials and Methods: The audit service was a remote audit program performed on a commercial lung phantom preloaded with film and alanine detectors. An alanine pellet was placed in the centre of the target simulated using silicone in a 3D-printed mould. Large film detectors were placed coronally through the target and the lung/ tissue interface and analysed using gamma analysis. The beam output was always checked on the same day with alanine dosimetry in water. We audited 29 plans from 14 centres up to now. Results: For the alanine results 28/29 plans were within 5 % with 19/29 plans being within 3 %. The passing rates were > 95 % for the film through the target for 27/29 plans and 17/29 plans for the film at the lung/tissue interface. For three plans the passing rate was < 90 % for the film on top of the lungs. Conclusions: The preliminary results were very satisfactory for both detectors. The high passing rates for the film in the interface region indicate good performance of the treatment planning systems. The phantom design was robust and performed well on several treatment systems.
Notes: Yalvac, B (corresponding author), Wetenschapspk 27, B-3590 Diepenbeek, Belgium.
burak.yalvac@uhasselt.be; brigitte.reniers@uhasselt.be
Keywords: SBRT;Dosimetry audit;Alanine/EPR dosimetry;Radiochromic film dosimetry
Document URI: http://hdl.handle.net/1942/42741
e-ISSN: 2405-6316
DOI: 10.1016/j.phro.2024.100544
ISI #: 001180546600001
Rights: 2024 The Author(s). Published by Elsevier B.V. on behalf of European Society of Radiotherapy & Oncology. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
Category: A1
Type: Journal Contribution
Appears in Collections:Research publications