Please use this identifier to cite or link to this item:
http://hdl.handle.net/1942/47708Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Van Oost, Catharina Nina | - |
| dc.contributor.author | Masci, Federica | - |
| dc.contributor.author | Malisse, Adelien | - |
| dc.contributor.author | Schyvens, An-Marie | - |
| dc.contributor.author | PETERS, Brent | - |
| dc.contributor.author | DIRIX, Hélène | - |
| dc.contributor.author | ROSS, Veerle | - |
| dc.contributor.author | WETS, Geert | - |
| dc.contributor.author | NEVEN, An | - |
| dc.contributor.author | Verbraecken, Johan | - |
| dc.contributor.author | Aerts, Jean-Marie | - |
| dc.date.accessioned | 2025-11-13T14:38:40Z | - |
| dc.date.available | 2025-11-13T14:38:40Z | - |
| dc.date.issued | 2025 | - |
| dc.date.submitted | 2025-11-12T15:36:48Z | - |
| dc.identifier.citation | Sensors, 25 (20) (Art N° 6319) | - |
| dc.identifier.uri | http://hdl.handle.net/1942/47708 | - |
| dc.description.abstract | Wearable devices are increasingly used for health and stress monitoring, yet their accuracy under dynamic, real-world conditions remains uncertain. This study validated the heart rate measurement accuracy of one chest-worn device (Zephyr BioHarness 3.0), a research-grade wrist-worn device (EmbracePlus), and five commercial wrist-worn wearable devices (Fitbit Charge 5, Fitbit Sense 2, Garmin Vivosmart 4, WHOOP 4.0, and Withings Scanwatch) against a 12-lead ECG using a 20 min protocol simulating real-life dynamics, including rest and varied-intensity walking. Device performance was evaluated across the full protocol and during transient states, defined as periods of rapid heart rate change. Accuracy and agreement were evaluated across per-second, 10 s, and 60 s resolutions. The Zephyr device showed a strong performance during all dynamic conditions. Among the wrist-worn devices, the Fitbit Charge 5 and Sense 2 showed the highest accuracy overall, while the Garmin Vivosmart 4 demonstrated greater stability during transitions. The WHOOP 4.0, Withings Scanwatch, and EmbracePlus devices performed acceptably during steady-state conditions, but were less accurate during transitions. Performance notably declined across all wrist-worn devices during transient states, with motion onset and large step changes in heart rate exacerbating measurement errors. Larger averaging windows improved accuracy by smoothing variability. The findings underscore that wrist-worn wearable devices may be better suited for average and trend heart rate monitoring rather than capturing acute dynamics. However, the Garmin and Fitbit devices showed suitable when requiring moderate accuracy during dynamic conditions. These results highlight the importance of context-specific validation and informed device selection to ensure effective use in health and stress-related applications. | - |
| dc.description.sponsorship | Funding: This research was funded by Flanders Innovation & Entrepreneurship—VLAIO, grant number HBC.2021.0387. We thank the BAKALA institute of KU Leuven for providing access to their equipment. | - |
| dc.language.iso | en | - |
| dc.publisher | MDPI | - |
| dc.rights | 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). | - |
| dc.subject.other | wearable devices | - |
| dc.subject.other | wearable devices | - |
| dc.subject.other | validation study | - |
| dc.subject.other | validation study | - |
| dc.subject.other | heart rate | - |
| dc.subject.other | heart rate | - |
| dc.subject.other | dynamic conditions | - |
| dc.subject.other | dynamic conditions | - |
| dc.subject.other | transient states | - |
| dc.subject.other | transient states | - |
| dc.subject.other | stress monitoring | - |
| dc.subject.other | stress monitoring | - |
| dc.title | Accuracy of Heart Rate Measurement Under Transient States: A Validation Study of Wearables for Real-Life Monitoring | - |
| dc.type | Journal Contribution | - |
| dc.identifier.issue | 20 | - |
| dc.identifier.volume | 25 | - |
| local.format.pages | 19 | - |
| local.bibliographicCitation.jcat | A1 | - |
| dc.description.notes | Van Oost, CN (corresponding author), Katholieke Univ Leuven, Dept Biosyst, B-3000 Leuven, Belgium. | - |
| dc.description.notes | nina.vanoost@kuleuven.be; federica.masci@kuleuven.be; | - |
| dc.description.notes | adelien.malisse@biorics.com; an-marie.schyvens@uantwerpen.be; | - |
| dc.description.notes | brent.peters@uhasselt.be; helene.dirix@uhasselt.be; | - |
| dc.description.notes | veerle.ross@uhasselt.be; geert.wets@uhasselt.be; an.neven@uhasselt.be; | - |
| dc.description.notes | johan.verbraecken@uza.be; jean-marie.aerts@kuleuven.be | - |
| local.publisher.place | MDPI AG, Grosspeteranlage 5, CH-4052 BASEL, SWITZERLAND | - |
| local.type.refereed | Refereed | - |
| local.type.specified | Article | - |
| local.bibliographicCitation.artnr | 6319 | - |
| dc.identifier.doi | 10.3390/s25206319 | - |
| dc.identifier.pmid | 41157371 | - |
| dc.identifier.isi | 001602744300001 | - |
| local.provider.type | wosris | - |
| local.description.affiliation | [Van Oost, Catharina Nina; Masci, Federica; Malisse, Adelien; Aerts, Jean-Marie] Katholieke Univ Leuven, Dept Biosyst, B-3000 Leuven, Belgium. | - |
| local.description.affiliation | [Schyvens, An-Marie; Verbraecken, Johan] Antwerp Univ Hosp, Multidisciplinary Sleep Disorders Ctr, B-2650 Edegem, Belgium. | - |
| local.description.affiliation | [Schyvens, An-Marie; Verbraecken, Johan] Univ Antwerp, Lab Expt Med & Pediat, B-2000 Antwerp, Belgium. | - |
| local.description.affiliation | [Peters, Brent; Dirix, Helene; Ross, Veerle; Wets, Geert; Neven, An] Hasselt Univ, Transportat Res Inst IMOB, Sch Transportat Sci, B-3500 Hasselt, Belgium. | - |
| local.description.affiliation | [Ross, Veerle] Evidence Based Psychol Ctr, Faresa, B-3570 Hasselt, Belgium. | - |
| local.uhasselt.international | no | - |
| item.accessRights | Open Access | - |
| item.fulltext | With Fulltext | - |
| item.fullcitation | Van Oost, Catharina Nina; Masci, Federica; Malisse, Adelien; Schyvens, An-Marie; PETERS, Brent; DIRIX, Hélène; ROSS, Veerle; WETS, Geert; NEVEN, An; Verbraecken, Johan & Aerts, Jean-Marie (2025) Accuracy of Heart Rate Measurement Under Transient States: A Validation Study of Wearables for Real-Life Monitoring. In: Sensors, 25 (20) (Art N° 6319). | - |
| item.contributor | Van Oost, Catharina Nina | - |
| item.contributor | Masci, Federica | - |
| item.contributor | Malisse, Adelien | - |
| item.contributor | Schyvens, An-Marie | - |
| item.contributor | PETERS, Brent | - |
| item.contributor | DIRIX, Hélène | - |
| item.contributor | ROSS, Veerle | - |
| item.contributor | WETS, Geert | - |
| item.contributor | NEVEN, An | - |
| item.contributor | Verbraecken, Johan | - |
| item.contributor | Aerts, Jean-Marie | - |
| Appears in Collections: | Research publications | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| Accuracy of Heart Rate Measurement Under Transient States_ A Validation Study of Wearables for Real-Life Monitoring.pdf | Published version | 1.88 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.