Title: Characterization of passive dosimeters in proton pencil beam scanning – A EURADOS intercomparison for mailed dosimetry audits in proton therapy centres
Authors: -Hubert, M. De Saint
Angelis, C. De
Knezevic, Z.
Michalec, B.
RENIERS, Brigitte 
Pyszka, E.
Stolarczyk, L.
Swakon, J.
Foltynska, G.
Wochnik, A.
Parisi, A.
Majer, M.
Harrison, R. M.
Kopec, R.
Vanhavere, F.
Olko, P.
Issue Date: 2021
Publisher: ELSEVIER SCI LTD
Source: Physica Medica-European Journal of Medical Physics, 82 , p. 134 -143
Abstract: The lack of mailed dosimetry audits of proton therapy centres in Europe has encouraged researchers of EURADOS Working Group 9 (WG9) to compare response of several existing passive detector systems in therapeutic pencil beam scanning. Alanine Electron Paramagnetic Resonance dosimetry systems from 3 different institutes (ISS, Italy; UH, Belgium and IFJ PAN, Poland), natLiF:Mg, Ti (MTS-N) and natLiF:Mg, Cu, P (MCP-N) thermoluminescent dosimeters (TLDs), GD-352M radiophotoluminescent glass dosimeters (RPLGDs) and Al2O3:C optically stimulated dosimeters (OSLDs) were evaluate. Dosimeter repeatability, batch reproducibility and response in therapeutic Pencil Beam Scanning were verified for implementation as mail auditing system. Alanine detectors demonstrated the lowest linear energy transfer (LET) dependence with an agreement between measured and treatment planning system (TPS) dose below 1%. The OSLDs measured on average a 6.3% lower dose compared to TPS calculation, with no significant difference between varying modulations and ranges. Both GD-352M and MCP-N measured a lower dose than the TPS and luminescent response was dependent on the LET of the therapeutic proton beam. Thermoluminescent response of MTS-N was also found to be dependent on the LET and a higher dose than TPS was measured with the most pronounced increase of 11%. As alanine detectors are characterized by the lowest energy dependence for different parameters of therapeutic pencil beam scanning they are suitable candidates for mail auditing in proton therapy. The response of luminescence detector systems have shown promises even though more careful calibration and corrections are needed for its implementation as part of a mailed dosimetry audit system.
Notes: De Saint-Hubert, M (corresponding author), Belgian Nucl Res Ctr SCK CEN, Boeretang 200, BE-2400 Mol, Belgium.
mdsainth@sckcen.be
Other: De Saint-Hubert, M (corresponding author), Belgian Nucl Res Ctr SCK CEN, Boeretang 200, BE-2400 Mol, Belgium. mdsainth@sckcen.be
Keywords: Alanine;Luminescence dosimetry;Mail auditing;Proton therapy
Document URI: http://hdl.handle.net/1942/34048
ISSN: 1120-1797
e-ISSN: 1724-191X
DOI: 10.1016/j.ejmp.2021.01.073
ISI #: WOS:000637335600006
Rights: 2021 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Category: A1
Type: Journal Contribution
Validations: ecoom 2022
Appears in Collections:Research publications

Files in This Item:
File Description SizeFormat 
1-s2.0-S1120179721000764-main.pdfPublished version2.3 MBAdobe PDFView/Open
Show full item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.