Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/39562
Title: Dual-energy CT evaluation of 3D printed materials for radiotherapy applications
Authors: Fonseca, Gabriel P.
REZAEIFAR, Behzad 
Lackner, Niklas
Haanen, Britt
RENIERS, Brigitte 
Verhaegen, Frank
Issue Date: 2023
Publisher: IOP Publishing Ltd
Source: PHYSICS IN MEDICINE AND BIOLOGY, 68 (3) (Art N° 035005)
Abstract: Objective. There is a continuous increase in 3D printing applications in several fields including medical imaging and radiotherapy. Although there are numerous advantages of using 3D printing for the development of customized phantoms, bolus, quality assurance devices and other clinical applications, material properties are not well known and printer settings can affect considerably the properties (e.g. density, isotropy and homogeneity) of the printed parts. This study aims to evaluate several materials and printer properties to identify a range of tissue-mimicking materials. Approach. Dual-energy CT was used to obtain the effective atomic number (Z (eff)) and relative electron density (RED) for thirty-one different materials including different colours of the same filament from the same manufacturer and the same type of filament from different manufacturers. In addition, a custom bone equivalent filament was developed and evaluated since a high-density filament with a composition similar to bone is not commercially available. Printing settings such as infill density, infill pattern, layer height and nozzle size were also evaluated. Main results. Large differences were observed for HU (288), RED (>10%) and Z (eff) (>50%) for different colours of the same filament due to the colour pigment. Results show a wide HU variation (-714 to 1104), RED (0.277 to 1.480) and Z (eff) (5.22 to 12.39) between the printed samples with some materials being comparable to commercial tissue-mimicking materials and good substitutes to a range of materials from lung to bone. Printer settings can result in directional dependency and significantly affect the homogeneity of the samples. Significance. The use of DECT to extract RED, and Z (eff) allows for quantitative imaging and dosimetry using 3D printed materials equivalent to certified tissue-mimicking tissues.
Notes: Fonseca, GP (corresponding author), Maastricht Univ, Med Ctr, GROW Sch Oncol & Reprod, Dept Radiat Oncol Maastro, Maastricht, Netherlands.
gabriel.paivafonseca@maastro.nl
Keywords: 3D printing;DECT;radiotherapy
Document URI: http://hdl.handle.net/1942/39562
ISSN: 0031-9155
e-ISSN: 1361-6560
DOI: 10.1088/1361-6560/acaf4a
ISI #: 000918238700001
Rights: 2023 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd. OPEN ACCESS Original content from this work may be used under the terms of the Creative Commons Attribution 4.0 licence.
Category: A1
Type: Journal Contribution
Appears in Collections:Research publications

Files in This Item:
File Description SizeFormat 
Dual-energy CT evaluation of 3D printed materials for radiotherapy applications.pdfPublished version1.67 MBAdobe PDFView/Open
Show full item record

WEB OF SCIENCETM
Citations

3
checked on Apr 22, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.