Title: Micro-patterned molecularly imprinted polymer structures on functionalized diamond-coated substrates for testosterone detection
Authors: KELLENS, Evelien 
BOVE, Hannelore 
VANDENRYT, Thijs 
LAMBRICHTS, Jeroen 
Dekens, Jolien
DRIJKONINGEN, Sien 
D'HAEN, Jan 
DE CEUNINCK, Ward 
THOELEN, Ronald 
JUNKERS, Tanja 
HAENEN, Ken 
ETHIRAJAN, Anitha 
Issue Date: 2018
Publisher: ELSEVIER ADVANCED TECHNOLOGY
Source: BIOSENSORS & BIOELECTRONICS, 118, p. 58-65
Abstract: Molecularly imprinted polymers (MIPs) can selectively bind target molecules and can therefore be advantageously used as a low-cost and robust alternative to replace fragile and expensive natural receptors. Yet, one major challenge in using MIPs for sensor development is the lack of simple and cost-effective techniques that allow firm fixation as well as controllable and consistent receptor material distribution on the sensor substrate. In this work, a convenient method is presented wherein microfluidic systems in conjunction with in situ photo-polymerization on functionalized diamond substrates are used. This novel strategy is simple, efficient, low-cost and less time consuming. Moreover, the approach ensures a tunable and consistent MIP material amount and distribution between different sensor substrates and thus a controllable active sensing surface. The obtained patterned MIP structures are successfully tested as a selective sensor platform to detect physiological concentrations of the hormone disruptor testosterone in buffer, urine and saliva using electrochemical impedance spectroscopy. The highest added testosterone concentration (500 nM) in buffer resulted in an impedance signal of 10.03 +/- 0.19% and the lowest concentration (0.5 nM) led to a measurable signal of 1.8 +/- 0.15% for the MIPs. With a detection limit of 0.5 nM, the MIP signals exhibited good linearity between a 0.5 nM and 20 nM concentration range. Apart from the excellent and selective recognition offered by these MIP structures, they are also stable during and after the dynamic sensor measurements. Additionally, the MIPs can be easily regenerated by a simple washing procedure and are successfully tested for their reusability.
Notes: [Kellens, Evelien; Bove, Hannelore; Vandenryt, Thijs; Lambrichts, Jeroen; Dekens, Jolien; Drijkoningen, Sien; D'Haen, Jan; De Ceuninck, Ward; Thoelen, Ronald; Junkers, Tanja; Haenen, Ken; Ethirajan, Anitha] Hasselt Univ, Inst Mat Res IMO, Wetenschapspk 1 & Agoralaan D, B-3590 Diepenbeek, Belgium. [Kellens, Evelien; Vandenryt, Thijs; Lambrichts, Jeroen; Drijkoningen, Sien; D'Haen, Jan; De Ceuninck, Ward; Thoelen, Ronald; Haenen, Ken; Ethirajan, Anitha] IMEC VZW, IMOMEC, Wetenschapspk 1, B-3590 Diepenbeek, Belgium. [Bove, Hannelore] Hasselt Univ, Biomed Res Inst BIOMED, Agoralaan Bldg C, B-3590 Diepenbeek, Belgium. [Junkers, Tanja] Monash Univ, Sch Chem, 19 Rainforest Walk, Clayton, Vic 3800, Australia.
Keywords: Microfluidics; Molecularly imprinted polymers; Biosensors and Bodyfluids;Microfluidics; Molecularly imprinted polymers; Biosensors and Body fluids
Document URI: http://hdl.handle.net/1942/27697
ISSN: 0956-5663
e-ISSN: 1873-4235
DOI: 10.1016/j.bios.2018.07.032
ISI #: 000444358000009
Category: A1
Type: Journal Contribution
Validations: ecoom 2019
Appears in Collections:Research publications

Files in This Item:
File Description SizeFormat 
kellens 1.pdf
  Restricted Access
Published version831.28 kBAdobe PDFView/Open    Request a copy
Manuscript_AfterRevision.pdfPeer-reviewed author version1.64 MBAdobe PDFView/Open
Show full item record

SCOPUSTM   
Citations

6
checked on Sep 3, 2020

WEB OF SCIENCETM
Citations

28
checked on Apr 14, 2024

Page view(s)

76
checked on Jul 5, 2022

Download(s)

244
checked on Jul 5, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.